| Automatic functions: |
| Selectable period of time for light
increasing |
0-59 min. Step = 1 min. |
| Selectable period of time for light
decreasing |
0-59 min. Step = 1 min. |
| Selectable point of time when
increasing light level reaches max. level |
Any time of day, Step = 1 min. |
| Selectable point of time when
light level starts decreasing |
Any time of day, Step = 1 min. |
| Selectable minimum light level |
0 - 100%, Step = 1% |
| Selectable maximum light level |
100 - 0%, Step = 1% |
| Selectable day/ night cycle period: |
10 - 250% of normal 24 hours cycle.
Step = 1%
( 2,4 - 60 hours) |
| Manual functions: |
| Start light increasing/ decreasing |
Yes |
| Stop/continue light increase/ decrease |
Yes |
| Turn light on/off immediately |
Yes |
| Turn from increasing to decreasing light and
vice versa. |
Yes |
| Constantly dimmed light |
Yes |
| Adjustment of constantly dimmed light |
Yes, Step = 1% |
| Technically and practically: |
| Line voltage |
220 - 240 Volts |
| Line frequency |
50 Hz |
| Type of lamp(s) |
Ordinary bulbs or halogen for 230 - 240
volts. |
| Load |
Min 25/ max 400 Watts lamps. |
| Fuse |
2 A/250V, Surge 1500A, 5x20 mm,
accessable from outside |
| Memory |
Saves all user settings for min. 10 years
after power dropout or disconnection. |
| Clock |
Embedded, synthesized |
| Clock stability |
Power line controlled |
| Clock recovery |
Clock freezes and saves data at power
drop-out or disconnection. Clock resumes running upon reconnection.
Clock data are saved for min. 10 years. |
| Line connection |
Fixed cable, 2 m. Plug w/ earth terminal.
(Continental European standard) |
| Lamp outlet |
Socket w/ earth terminal (Continental European
standard) |
| L x W x H |
21,7 x 11,1 x 5,2 cm |
| User Manual |
18 pages,
English and Norwegian w. examples |
| Safety and quality matters |
| Safety class |
CENELEC class I |
| Quality Assurance Standard |
CCA 201 |